• 7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter
  • 7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter
  • 7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter
  • 7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter
  • 7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter
  • 7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter

7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter

Methodology: Reflectance Photometer
Test Time: Total Cholesterol (Tc), High Density Lipoprotein C
Measurement Range: Tc: 2.59mmol/L-12.93 Mmol/L(100mg/Dl-500mg/Dl ) HD
Specimen: Whole Blood(Capillary Blood, Venous Whole Blood),
Units of Measurement: Mg/Dl or Mmol/L
Weight: 90g
Samples:
US$ 160/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
DBM-101
Pollution Degree of The Intended Environ
2
System Operating Altitude
Max. 2000 M
Power Source
Charging Battery; Note: During Charging, The Meter
Memory
500 Records
Transport Package
34.5*32.6*24cm
Specification
35 μ L or 10 μ L
Trademark
SoyMed
Origin
China Zhejiang
Production Capacity
1000000/Month

Product Description

 

Product Description

 

Product Description
7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter
Name:Dry Biochemical Analysis Meter
Identification 
Meter
: DBM-101
Test strips: LPS-101,RFS-101,HLS-101,TCS-101,TGS-101,UAS-101,URS-
101,CR


Main Features of Dry Biochemical Analysis Meter
I One meter measures 6 parameters: Total Cholesterol,HDL, Triglycerides, Creatinine, Uric acid, Urea
II Just 35μL fingertip blood specimen, 2mins to read Lipid tests and 5 mins to read Renal function tests
III APP for health management on smartphone
IV Li-ion battery, rechargeable
V Bluetooth enables printing results by thermal printer 
VI Certificate: CE

 


 
Please check the following requirements when you first receive our products:
Unpacking, Checking delivery for completeness, Checking for damage during
transport. If you have any question, please contact the manufacturer.

 
7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter

Meter display
 
7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter



The Dry Biochemical Analysis Meter reads the test strips and displays the concentrations of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL),Triglycerides (TG), Uric Acid (UA), Creatinine (CR) and Urea (UR). Use this diagram to become familiar with all the parts of the meter.

Specimen Application
 
The Dry Biochemical Test strips are plastic devices that work with the Dry Biochemical Analysis Meter to measure the Total Cholesterol (TC), High Density Lipoprotein Cholesterol(HDL), Triglycerides (TG), Uric acid (UA), Creatinine (CR) and Urea (UR), Blood ketone(KET) concentration in whole blood,Aplasma and serum.Test strip appears as shown right:
7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter

The Precision
 
Iterm Range of sample SD
TC 2.59mmol/L-5.17mmol/L(100mg/dL-200mg/dL) SD<0.39mmol/L
(<15.1mg/dL)
  5.18mmol/L-12.93mmol/L(201mg/dL-500mg/dL) CV<7.5%
HDL 0.39mmol/L-0.78mmol/L (15mg/dL-30mg/dL) SD<0.06mmol/L
(<2.3mg/dL)
  0.79mmol/L-2.59mmol/L(31mg/dL-100mg/dL) CV<7.5%
TG 0.51mmol/L-1.13mmol/L(45mg/dL-100mg/dL) SD<0.08mmol/L
(<7.5mg/dL)
  1.14mmol/L-7.34mmol/L(101mg/dL-650mg/dL) CV<7.5%
UA 0.090mmol/L-0.300mmol/L(1.51mg/dL-5.04mg/dL) SD<0.023mmol/L
(<0.38mg/dL)
  0.301mmol/L-1.200mmol/L (5.05mg/dL-20.17mg/dL) CV<7.5%
CR 0.044mmol/L-0.150mmol/L (0.50mg/dL-1.70mg/dL) CV<7.5%
  0.151mmol/L-1.320mmol/L (1.71mg/dL-14.93mg/dL) SD<0.75mmol/L
(<4.50mg/dL)
UR 0.90mmol/L-10.00mmol/L (5.41mg/dL-60.06mg/dL) SD<0.75mmol/L
(<4.50mg/dL)
  10.01mmol/L-40.00mmol/L(60.07mg/dL-240.24mg/dL) CV<7.5%
KET 0.02mmol/L-1.00mmol/L (0.21mg/dL-10.41mg/dL) SD<0.08mmol/L
(<0.78mg/dL)
  1.01mmol/L-6.00mmol/L(10.42mg/dL-62.46mg/dL) CV<7.5%


The Accuracy
 
Iterm Range of sample Bias
TC 2.59mmol/L-5.17mmol/L(100mg/dL-200mg/dL) ≤±1.03mmol/L
(±40mg/dL)
  5.18mmol/L-12.93mmol/L(201mg/dL-500mg/dL) ≤±20%
HDL 0.39mmol/L-0.78mmol/L (15mg/dL-30mg/dL) ≤±0.16mmol/L
(±6mg/dL)
  0.79mmol/L-2.59mmol/L(31mg/dL-100mg/dL) ≤±20%
TG 0.51mmol/L-1.13mmol/L(45mg/dL-100mg/dL) ≤±0.23mmol/L
(±20mg/dL)
  1.14mmol/L-7.34mmol/L(101mg/dL-650mg/dL) ≤±20%
UA 0.090mmol/L-0.300mmol/L(1.51mg/dL-5.04mg/dL) ≤±0.060mmol/L
(±1.01mg/dL)
  0.301mmol/L-1.200mmol/L (5.05mg/dL-20.17mg/dL) ≤±20%
CR 0.044mmol/L-0.150mmol/L (0.50mg/dL-1.70mg/dL) ≤±0.030mmol/L
(±0.34mg/dL)
  0.151mmol/L-1.320mmol/L (1.71mg/dL-14.93mg/dL) ≤±20%
UR 0.90mmol/L-10.00mmol/L (5.41mg/dL-60.06mg/dL) ≤±2.00mmol/L
(±12.01mg/dL)
  10.01mmol/L-40.00mmol/L(60.07mg/dL-240.24mg/dL) ≤±20%
KET 0.02mmol/L-1.00mmol/L (0.21mg/dL-10.41mg/dL) ≤±0.20mmol/L
(±2.08mg/dL)
  1.01mmol/L-6.00mmol/L (10.42mg/dL-62.46mg/dL) ≤±20%


 
Detailed Photos

7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter

 

Company Profile
7 in 1 Medical Health Care High Quality CE Approved Medical Dry Biochemical Renal Blood Lipid Function Analysis Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
5000000 RMB
Plant Area
101~500 square meters